

Sports Equipment Manufacturer
Technical · Floor construction
The surface is what players see; the subfloor is what they feel. Shock absorption, ball bounce and long-term stability come from the joists, resilient pads and load-bearing layers beneath the boards. LDK builds four subfloor systems – two permanent, two dismountable – and supplies each one as a complete system.
The layers
| Component | What it does and how LDK builds it | Used in |
|---|---|---|
| Moisture barrier | Polyethylene (PE) moisture-proof film laid over the slab to keep moisture away from the timber. | W01 · W02 |
| Resilient shock-absorbing pads | Professional sports flooring pads that give consistent shock absorption and keep their elasticity under long-term and varying loads: 12 mm in W01 and W02, 20 mm in W05. W03 uses an elastic shock-absorbing rubber mat. | All four |
| Joists | 24 mm LVL joists (W01), double-layer 30 × 50 mm solid pine battens in a grid (W02), 30 mm LVL main joists (W05) or keelson plates (W03). | All four |
| Load-bearing layer | 12 mm high-strength laminated plywood (W01), a 12 mm composite middle layer (W05) or a rough board / load panel (W03). | W01 · W05 · W03 |
| Non-woven fabric | Installed between the rough board and the surface panel for moisture resistance, sound absorption and noise reduction. | W01 · W02 |
| Connection hardware | Interlocking grooves with metal pull tabs between modules (W05); ground anchors and steel latches (W03). | W05 · W03 |
| Surface panel | 22 mm North American maple or Russian birch (W01, W02, W05); solid wood composite panels with a high-grade maple surface (W03). | All four |
Four systems side by side
| LDK25W01 Single-Joist | LDK25W02 Double-Joist | LDK25W05 Modular | LDK25W03 Portable Competition | |
|---|---|---|---|---|
| Type | Permanent | Permanent | Dismountable, modular | Dismountable |
| Total thickness | 70 mm | 114 mm | 84 mm | 88 mm |
| Surface | 22 mm maple or birch | 22 mm maple or birch | 22 mm maple or birch | High-grade maple on solid wood composite panels |
| Joists | 24 mm LVL | Double-layer 30 × 50 mm solid pine grid | 30 mm LVL main joists | Keelson plates |
| Resilient layer | 12 mm pads | 12 mm pads | 20 mm pads | Elastic rubber shock-absorbing mat |
| Connection | Fixed | Fixed | Interlocking grooves + metal pull tabs | Ground anchors / steel latches |
| Standard | – | – | Built to FIBA standards | Built to FIBA standards |
| Finish | Professional sports flooring coating imported from the USA | Multilayer, waterproof, wear-resistant sports coating imported from the USA | ||
| Product page | View W01 → | View W02 → | View W05 → | View W03 → |
Permanent systems
One layer of 24 mm LVL joists on 12 mm resilient pads carries a 12 mm laminated plywood load panel and the 22 mm surface. LVL (laminated veneer lumber) offers high strength, good toughness and dimensional stability.
Explore LDK25W01 →Two layers of 30 × 50 mm solid pine battens are laid crosswise in a grid on 12 mm resilient pads, with the 22 mm surface on top.
Explore LDK25W02 →Both are permanent systems for courts used every day. The choice depends on the venue, the sports played, the available floor height and the budget. Send us your court size and use, and we will recommend one. Venue, sport, and available floor height drive this selection; compare support options in the single vs double batten sports floorsingle vs double batten sports floor guide.
Ask for a recommendation →Dismountable systems
Each module combines a 22 mm surface, a 12 mm composite middle layer and 30 mm LVL main joists on 20 mm resilient pads. Modules lock together through interlocking grooves and metal pull tabs. Built to FIBA standards.
Explore LDK25W05 →Built from an elastic rubber shock-absorbing mat, keelson plates, ground anchors and steel latches, a rough board / load panel and solid wood composite panels with a high-grade maple surface. Built to FIBA standards and designed to be dismantled and reinstalled, so it can also be rented out.
Explore LDK25W03 →Allow for panel handling, an assembly crew, transport routes and dry storage between events.
View dismountable systems →Before the subfloor goes down
Every subfloor system needs a flat, dry, strong slab: within 5 mm under a 2 m straightedge, C25 concrete or stronger, and moisture content below 14%. The slab must be flat and dry before installation; review moisture-control details in the gym floor moisture barriergym floor moisture barrier guide.
FAQ
LDK uses 24 mm LVL joists in LDK25W01, double-layer 30 × 50 mm solid pine battens in LDK25W02 and 30 mm LVL main joists in LDK25W05. LDK25W03 uses keelson plates.
12 mm in LDK25W01 and LDK25W02, and 20 mm in LDK25W05. LDK25W03 uses an elastic rubber shock-absorbing mat.
LDK25W01 is 70 mm, LDK25W02 is 114 mm, LDK25W05 is 84 mm and LDK25W03 is 88 mm.
Yes. LDK25W01 and LDK25W02 include a polyethylene moisture-proof film.
North American maple or Russian birch for W01, W02 and W05. W03 uses a high-grade maple surface.
Tell us the sport, court size and how the hall will be used. We will recommend a system and send a free layout design with your quotation.